JJC-6 Insulation Piercing Connector
The JJC-6 insulation piercing connector branches 120-240/10-120 mm² LV-ABC conductors without stripping insulation. Tightened to 35 Nm.
- Model: JJC-6
- Product Type: IPC
- Cross-Section / Cable Range: 120-240/10-120mm²
- Torque: 35Nm
Product Description
The JJC-6 is an insulation piercing connector (IPC) for branching conductors in low-voltage aerial bundled cable (LV-ABC) networks. Instead of stripping the insulation, the connector uses alloy bolts whose teeth cut through the insulation to reach the conductor, then clamp down on it.
Because the insulation is never removed, no separate joint enclosure or waterproofing tape is needed at the branch point. This shortens installation time on pole-top work and removes one of the common failure points — an exposed joint that admits moisture and corrodes over time.
Install with a calibrated torque wrench, tightened to 35Nm. The piercing teeth form a gas-tight seal around both the conductor and the insulation, so the joint stays stable under long-term exposure to moisture, dust and UV.
Technical Specifications
| Item | Specification |
| Model | JJC-6 |
| Product Type | Insulation Piercing Connector (IPC) |
| Cross-Section / Cable Range | 120-240/10-120mm² |
| Tightening Torque | 35Nm |
| Product Category | Aerial Cable Accessories |
| Manufacturer | GGLDF |
How to Select the Right Model
The range above is written as main side / branch side. The first figure is the conductor the connector sits on, the second is the conductor being branched off to. Match both figures to your actual conductors before ordering.
| Conductor class | Models and ranges |
| Small conductor — up to 50 mm² on both sides | PC4-35 — 4-35/4-35mm² PC102 — 6-50/4-25mm² CD21 — 10-35/2.5-35mm² |
| Medium conductor — up to 150 mm² | EP — 16-95/1.5-16mm² EP-CT — 16-95/1.5-16mm² EP-BT — 16-95/1.5-16mm² SY95 — 16-95/4-50mm² PC2-150BT — 16-150/4-50mm² PC101 — 16-95/1.5-10mm² PC-150-10 — 10-150/1.5-10mm² CTH35 — 16-95/4-50mm² CD71 — 35-95/4-70mm² PC3-95 — 25-95/25-95mm² JBC-2 — 35-120/35-120mm² JBC-1 — 35-70/6-35mm² CPL-150 — 35-150/35-150mm² CPL-95 — 16-95/16-25mm² JJC16-150 — 35-150/35-150mm² JJC2-150 — 50-150/6-50mm² JJC2-95 — 16-95/4-50mm² |
| Large conductor — above 150 mm² | JJC-6 — 120-240/10-120mm² JBC-3 — 50-240/50-240mm² |
Aluminium conductors: if either side is aluminium, use a bi-metallic bolt — EP-BT. Aluminium and copper react in the presence of moisture, which corrodes the contact face and raises resistance over time.
If your conductors fall outside every range listed above, send us the cross-sections and we will confirm which model fits rather than guess.
Key Advantages
- No stripping or cutting of insulation required — fewer installation steps on site
- Gas-tight seal around conductor and insulation; no separate joint enclosure needed
- Rated 35Nm tightening torque for a repeatable mechanical connection
Typical Applications
- Branch and tap-off connections in low-voltage aerial bundled cable networks.
- LV-ABC overhead distribution line installation and maintenance.
- Branch connections to service drops on distribution poles.
- Grid extension and rural electrification projects.
Send us the conductor cross-sections, quantity and destination port for a quotation with pricing and lead time. View all insulation piercing connector models →